REMKO KWK SERIES Wall and ceiling chests as 2-pipe or 4-pipe system

Variant EDV-Nr. Cooling capacity
KWK 130 1662210 1,3 kW
KWK 140 1662220 1,5 kW
KWK 200 1662230 2,0 kW
KWK 220 1662240 2,2 kW
KWK 280 1662250 2,8 kW
KWK 300 1662260 3,1 kW
KWK 360 1662270 3,6 kW
KWK 420 1662280 4,2 kW
KWK 590 1662290 5,9 kW
KWK 680 1662300 6,8 kW
KWK 740 1662310 7,4 kW
KWK 870 1662320 8,7 kW

Variant

REMKO KWK SERIES

The wall and ceiling chests are characterised by a discreet design

The wall and ceiling chests can be used for both vertical installation on the wall or for horizontal installation under the  ceiling. They are extremely well-suited for installation in offices and meeting rooms, banks, business and in private residences.

REMKO wall or ceiling chests are equipped with the latest technology and offer exceptional flexibility in terms of installation. The medium connections are fitted as standard in the housing on the left-hand side. The controller can optionally be mounted right on the device or on a wall. It is possible for the connections and controls to exchange sides. The standard colour of the elegant housing is white, and the outlet grille is finished in white plastic. The air passes through a reclaimable filter in the unit. An extremely low-noise three-stage tangential fan provides impeccable air distribution and maximises vent output. The copper-aluminium register is designed for medium temperatures of up to 80°C. The unit can easily be upgraded to a quadrupleconductor system through the installation of a heating register. An electrical heating resistor enables the additional heating of the rooms.

  • The ideal solution for optically discreet air-conditioning
  • Low-noise unit operation
  • Simple equipping of the device in a four-pipe design
  • For horizontal and vertical installations

Technical data

Variant KWK 130 KWK 140 KWK 200 KWK 220 KWK 280 KWK 300 KWK 360 KWK 420 KWK 590 KWK 680 KWK 740 KWK 870
Cooling capacity 1,3 kW 1,5 kW 2,0 kW 2,2 kW 2,8 kW 3,1 kW 3,6 kW 4,2 kW 5,9 kW 6,8 kW 7,4 kW 8,7 kW
Heating capacity 1,6 kW 1,9 kW 2,2 kW 2,6 kW 3,2 kW 3,7 kW 4,0 kW 4,7 kW 6,5 kW 7,5 kW 7,9 kW 9,5 kW
Nominal air volume per stage 120/199/263 m³/h 147/228/314 m³/h 173/264/349 m³/h 199/313/416 m³/h 262/392/518 m³/h 294/451/610 m³/h 282/462/611 m³/h 328/524/751 m³/h 468/724/1001 m³/h 538/843/1203 m³/h 524/873/1195 m³/h 612/1037/1489 m³/h
Sound pressure level per stage 22/31/38 dB(A) 24/34/42 dB(A) 23/32/39 dB(A) 23/32/39 dB(A) 28/35/42 dB(A) 28/38/45 dB(A) 22/32/39 dB(A) 24/36/44 dB(A) 29/40/47 dB(A) 32/43/51 dB(A) 29/38/45 dB(A) 31/41/49 dB(A)
Sound power level per stage 30/39/46 dB(A) 32/42/50 dB(A) 31/40/47 dB(A) 33/44/51 dB(A) 34/43/50 dB(A) 36/46/53 dB(A) 30/40/47 dB(A) 32/44/52 dB(A) 37/48/55 dB(A) 40/51/59 dB(A) 37/46/53 dB(A) 39/49/57 dB(A)
Power supply 230/1~/50 V/Ph/Hz 230/1~/50 V/Ph/Hz 230/1~/50 V/Ph/Hz 230/1~/50 V/Ph/Hz 230/1~/50 V/Ph/Hz 230/1~/50 V/Ph/Hz 230/1~/50 V/Ph/Hz 230/1~/50 V/Ph/Hz 230/1~/50 V/Ph/Hz 230/1~/50 V/Ph/Hz 230/1~/50 V/Ph/Hz 230/1~/50 V/Ph/Hz
Electr. nominal power consumption 35 W 44 W 39 W 49 W 51 W 65 W 72 W 92 W 121 W 145 W 145 W 179 W
Electr. nominal current consumption 0,15 A 0,19 A 0,17 A 0,22 A 0,24 A 0,31 A 0,29 A 0,38 A 0,56 A 0,69 A 0,69 A 0,78 A
Operation pressure, max. 600 kPa 600 kPa 600 kPa 600 kPa 600 kPa 600 kPa 600 kPa 600 kPa 600 kPa 600 kPa 600 kPa 600 kPa
Medium connections 1/2 inch 1/2 inch 1/2 inch 1/2 inch 1/2 inch 1/2 inch 1/2 inch 1/2 inch 1/2 inch 1/2 inch 1/2 inch 1/2 inch
Nominal medium flow 0,23 m³/h 0,26 m³/h 0,34 m³/h 0,38 m³/h 0,47 m³/h 0,53 m³/h 0,62 m³/h 0,72 m³/h 1,02 m³/h 1,17 m³/h 1,27 m³/h 1,49 m³/h
Nominal medium flow (heating) 0,28 m³/h 0,32 m³/h 0,39 m³/h 0,45 m³/h 0,55 m³/h 0,63 m³/h 0,68 m³/h 0,81 m³/h 1,11 m³/h 1,30 m³/h 1,36 m³/h 1,62 m³/h
Nominal pressure loss, internal ³) 4,3 kPa 5,3 kPa 11,3 kPa 14,2 kPa 7,8 kPa 9,5 kPa 14,0 kPa 22,0 kPa 16,0 kPa 18,0 kPa 10,0 kPa 15,5 kPa
Nominal pressure loss, internal heating coil 5,3 kPa 6,8 kPa 11,8 kPa 15,3 kPa 8,9 kPa 11,2 kPa 14,8 kPa 20,1 kPa 25,5 kPa 33,5 kPa 14,6 kPa 19,9 kPa
Medium volume cooling coil / heating coil 0,6 l 0,6 l 0,9 l 0,9 l 1,1 l 1,1 l 1,4 l 1,4 l 2,4 l 2,4 l 3,0 l 3,0 l
Condensate drainage connection 19 mm 19 mm 19 mm 19 mm 19 mm 19 mm 19 mm 19 mm 19 mm 19 mm 19 mm 19 mm
Dimensions h/w/d 478/659/219 mm 478/659/219 mm 478/809/219 mm 478/809/219 mm 478/959/219 mm 478/959/219 mm 478/1109/219 mm 478/1109/219 mm 525/1409/230 mm 525/1409/230 mm 525/1709/230 mm 525/1709/230 mm
Weight 14,0 kg 14,0 kg 17,0 kg 17,0 kg 20,0 kg 20,0 kg 23,0 kg 23,0 kg 25,0 kg 35,0 kg 47,0 kg 47,0 kg
Protection class IP X0 IP X0 IP X0 IP X0 IP X0 IP X0 IP X0 IP X0 IP X0 IP X0 IP X0 IP X0

Accessories / Spare parts

Variant
Loading ...
Loading ...

Downloads

Variant
Language
Pictures
REMKO KWK 130 jpg, 0.1 MB
REMKO KWK 130 jpg, 1.9 MB
REMKO KWK 130 jpg, 0.2 MB
Assembly drawings
REMKO KWK 130 jpg, 0.4 MB

Cooling load calculation for air-conditioners

The following rule of thumb applies when calculating the cooling capacity:
Approximately 30 W of cooling capacity are required per cubic meter. The cooling capacity for a room with a surface area of 28 m2 and height of 2.5 m can be calculated as follows:

28 m2 x 2,5 m x 30 W/m3 = 2.100 Watt (2,1 kW)

We recommend that you always calculate the cooling capacity for the room precisely.

Cooling load calculation Calculate required cooling capacity

Cooling load calculation