REMKO PWL HK SERIES Ceiling ventilation units for cooling and heating

Variant EDV-Nr. Cooling capacity
PWL 101 HK 1688101 5,0 kW
PWL 102 HK 1688102 7,8 kW
PWL 103 HK 1688103 10,5 kW
PWL 201 HK 1688201 5,3 kW
PWL 202 HK 1688202 10,5 kW
PWL 203 HK 1688203 13,7 kW
PWL 301 HK 1688301 6,8 kW
PWL 302 HK 1688302 10,8 kW
PWL 303 HK 1688303 17,6 kW

Variant

REMKO PWL HK SERIES

Modern technology in an attractive design

The individually adjustable fins in the upper and lower parts of the housing allow optimum air distribution and thus provide a comfortable room climate. Their use in showrooms or other customer areas is possible thanks to their low sound pressure levels and their fine design. Ease of service and a simple, uncomplicated assembly are the characteristic features of these units. The media connections and the main cabling can be installed out of sight in the false ceiling. The elegant plastic housing can easily be removed from its bearing elements thanks to the rapid release couplings. PWL-HK series units are fitted as standard with a high-performance condensate pump.

  • Low-noise unit operation
  • Service-friendly
  • Universal use
  • Self-extinguishing plastic housing, fire class V-0

Heating in low-ceilinged rooms

Heating in high-ceilinged rooms

Cooling in low-ceilinged rooms

Cooling in high-ceilinged rooms


Technical data

Variant PWL 101 HK PWL 102 HK PWL 103 HK PWL 201 HK PWL 202 HK PWL 203 HK PWL 301 HK PWL 302 HK PWL 303 HK

Accessories / Spare parts

Variant
Loading ...
Für dieses Gerät stehen kein Ersatzteile zur Verfügung.

Downloads

Variant
Language

User manuals

Declarations of conformity

Pictures
REMKO PWL 101 HK jpg, 0.2 MB
Assembly drawings
REMKO PWL 101 HK jpg, 0.1 MB

Cooling load calculation for air-conditioners

The following rule of thumb applies when calculating the cooling capacity:
Approximately 30 W of cooling capacity are required per cubic meter. The cooling capacity for a room with a surface area of 28 m2 and height of 2.5 m can be calculated as follows:

28 m2 x 2,5 m x 30 W/m3 = 2.100 Watt (2,1 kW)

We recommend that you always calculate the cooling capacity for the room precisely.

Cooling load calculation Calculate required cooling capacity

Cooling load calculation