ATY SERIES - Bild 56823 ATY SERIES - Bild 66668 ATY SERIES - Bild 56825

REMKO ATY SERIES Design wall-mounted units for cooling and heating

Variant EDV-Nr. Cooling capacity
ATY 266 DC 1624460 2,6 (1,2-3,3) kW
ATY 356 DC 1624465 3,5 (1,3-4,4) kW

Variant

REMKO ATY SERIES Design wall-mounted units for cooling and heating

Design that fits the ambience

The exclusive high-gloss design with real-glass, mirrored front panel and high level of comfort differentiate our ARTstyle range from traditional air conditioning units and blend them harmonious into every room of your home. Thanks to state-of-the-art inverter technology, our air conditioners work every efficiently and quietly. This translates to maximum comfort, as temperature fluctuations in exiting air are reduced to a minimum.

  • Anthracite design housing with real glass mirror front panel
  • Automated deactivation of the lighting when dark through integrated light sensor
  • 3D swing function with horizontal and vertical air distribution
  • Programmable 24-hour timer function
  • Integrated ion generator for improving room air
  • Low-noise unit operation (silent mode)
  • Frost protection function - heating with set value of 8°C
  • The outdoor units are filled with R32 refrigerant at the factory
    (line length up to 5m)
  • Also available as multi-split solution

Technical data

Variant ATY 266 DC ATY 356 DC
Cooling capacity 2,64 (1,23-3,29) kW 3,51 (1,26-4,44) kW
Energy efficiency class (cooling) A++ A++
Energy efficiency ratio SEER 6,7 6,1
Power consumption cooling, annual, QCE 132 kWh 1,21 kWh
Heating capacity 2,93 kW 3,81 kW
Energy efficiency class (heating) A+ A+
Energy efficiency ratio SCOP 4,0 4,0
Power consumption heating, annual, QHE 785 kWh 922 kWh
Refrigerant R32 R32
GWP value 675 675
Refrigerant, basic amount 0,80 kg 0,80 kg
CO2 Equivalent 0,54 t 0,54 t
Operating range (room size) 80 m³ 110 m³
Operating range, indoor unit +17 bis +30 °C +17 bis +30 °C
Operating range, cooling +5 bis +30 °C +5 bis +30 °C
Operating range, heating +5 bis +50 °C +5 bis +50 °C
Fan stages 5 5
Nominal air volume per stage 305/421/530 m³/h 305/421/530 m³/h
Sound pressure level per stage, indoor unit 21/26/31/37/39 dB(A) 22/27/30/37/38 dB(A)
Soundpower indoor unit max 50 dB(A) 50 dB(A)
Soundpower outdoor unit max 63 dB(A) 63 dB(A)
Power supply 230/1~/50 V/Ph/Hz 230/1~/50 V/Ph/Hz
Refrigerant connection injection 1/4 inch 1/4 inch
Refrigerant connection, suction pipe 3/8 inch 3/8 inch
Condensate draining connection Ø 16 mm 16 mm
Refrigerant pipework, lenght/height max. 25/10 m 25/10 m
Dimensions indoor unit h/w/d 312/897/182 mm 312/897/182 mm
Dimensions outdoor unit h/w/d 555/770/300 mm 555/770/300 mm
Weight indoor-/outdoor unit 9,5/27,0 kg 9,9/27,0 kg

Accessories / Spare parts

Variant
Loading ...
Für dieses Gerät stehen kein Ersatzteile zur Verfügung.

Downloads

Variant
Language
Pictures
REMKO ATY 266 DC AT jpg, 0.5 MB
REMKO ATY 266 DC IT jpg, 0.7 MB

Cooling load calculation for air-conditioners

The following rule of thumb applies when calculating the cooling capacity:
Approximately 30 W of cooling capacity are required per cubic meter. The cooling capacity for a room with a surface area of 28 m2 and height of 2.5 m can be calculated as follows:

28 m2 x 2,5 m x 30 W/m3 = 2.100 Watt (2,1 kW)

We recommend that you always calculate the cooling capacity for the room precisely.

Cooling load calculation Calculate required cooling capacity

Cooling load calculation