REMKO ATY SERIES

Variant EDV-Nr. Cooling capacity
ATY 266 1623370 2,6 kW
ATY 356 1623375 3,5 kW

Variant

Technical data

Variant ATY 266 ATY 356
Cooling capacity 2,6 kW 3,5 kW
Heating capacity 2,9 kW 3,8 kW
Operating range (room size) 80 m³ 110 m³
Operating range, indoor unit +17 bis +30 °C +17 bis +30 °C
Nominal air volume per stage 240/300/400 m³/h 270/350/500 m³/h
Sound pressure level per stage, indoor unit 26/31/37 dB(A) 27/30/37 dB(A)
Soundpower indoor unit max 51 dB(A) 49 dB(A)
Power supply 230/1~/50 V/Ph/Hz 230/1~/50 V/Ph/Hz
Refrigerant connection injection 1/4 inch 1/4 inch
Refrigerant connection, suction pipe 3/8 inch 3/8 inch
Condensate draining connection Ø 18 mm 18 mm
Dimensions indoor unit h/w/d 312/897/182 mm 312/897/182 mm
Weight indoor-/outdoor unit 9,5 kg 9,9 kg

Accessories / Spare parts

Variant
Loading ...
Für dieses Gerät stehen kein Ersatzteile zur Verfügung.

Downloads

Variant
Language
Pictures
1623370_B_1_1_1.jpg jpg, 0.7 MB

Cooling load calculation for air-conditioners

The following rule of thumb applies when calculating the cooling capacity:
Approximately 30 W of cooling capacity are required per cubic meter. The cooling capacity for a room with a surface area of 28 m2 and height of 2.5 m can be calculated as follows:

28 m2 x 2,5 m x 30 W/m3 = 2.100 Watt (2,1 kW)

We recommend that you always calculate the cooling capacity for the room precisely.

Cooling load calculation Calculate required cooling capacity

Cooling load calculation