REMKO RVT SERIES Wall-mounted units for cooling and heating

Variant EDV-Nr. Cooling capacity
RVT 264 DC 1623710 2,6 (1,2-3,4) kW
RVT 354 DC 1623720 3,5 (1,4-4,6) kW
RVT 524 DC 1623730 5,3 (2,0-6,2) kW
RVT 684 DC 1623740 7,3 (3,0-8,4) kW

Variant

REMKO RVT SERIES

The ideal combination of comfort and aesthetics

The inverter air-conditioners of the REMKO RVT series function in a particularly efficient and environmentally sound manner thanks to the new refrigerant R32. The indoor units of the RVT series will persuade you with their modern, matt surface. The innovative display is only visible during operation. The display is projected through the housing, therefore stylishly rounding off the design. Due to contacts for external activation and deactivation in the standard version, in addition to an integrated alarm contact, the RVT units are also suitable for the air-conditioning of technical applications.

  • 3D swing function with horizontal and vertical air distribution
  • Programmable 24-hour timer function
  • Floating contacts for external start/stop and alarm forwarding
  • Low-noise unit operation (silent mode)
  • Frost protection function - heating with set value of 8°C
  • Microprocessor-controlled device technology
  • The outdoor units are filled with R32 refrigerant at the factory
    (line length up to 5 m)

RVT series in split design


Technical data

Variant RVT 264 DC RVT 354 DC RVT 524 DC RVT 684 DC
Cooling capacity 2,6 (1,2-3,4) kW 3,5 (1,4-4,6) kW 5,3 (2,0-6,2) kW 7,3 (3,0-8,4) kW
Energy efficiency class (cooling) A++ A++ A++ A++
Energy efficiency ratio SEER 7,5 6,3 7,1 6,6
Power consumption cooling, annual, QCE 124 kWh 194 kWh 261 kWh 387 kWh
Heating capacity 2,7 (0,8-3,9) kW 2,5 (0,9-5,1) kW 4,0 (1,3-7,0) kW 5,5 (2,1-9,4) kW
Energy efficiency class (heating) A+ A+ A+ A+
Energy efficiency ratio SCOP 4.1 4,0 4,0 4,0
Power consumption heating, annual, QHE 865 kWh 875 kWh 1400 kWh 1925 kWh
Refrigerant R32 R32 R32 R32
GWP value 675 675 675 675
Refrigerant, basic amount 0,70 kg 0,80 kg 1,25 kg 1,60 kg
CO2 Equivalent 0,47 t 0,54 t 0,84 t 1,08 t
Operating range (room size) 80 m³ 110 m³ 160 m³ 230 m³
Operating range, indoor unit +17 bis +30 °C +17 bis +30 °C +17 bis +30 °C +17 bis +30 °C
Operating range, cooling +5 bis +50 °C +5 bis +50 °C +5 bis +50 °C +5 bis +50 °C
Operating range, heating +5 bis +30 °C +5 bis +30 °C +5 bis +30 °C +5 bis +30 °C
Fan stages 5 5 5 5
Nominal air volume per stage 329/433/486 m³/h 360/490/550 m³/h 550/720/810 m³/h 650/970/1050 m³/h
Sound pressure level per stage, indoor unit 22/29/34/41/42 dB(A) 23/30/37/41/43 dB(A) 24/33/41/45/48 dB(A) 27/35/44/46/51 dB(A)
Soundpower indoor unit max 53 dB(A) 54 dB(A) 57 dB(A) 59 dB(A)
Soundpower outdoor unit max 58 dB(A) 60 dB(A) 60 dB(A) 65 dB(A)
Power supply 230/1~/50 V/Ph/Hz 230/1~/50 V/Ph/Hz 230/1~/50 V/Ph/Hz 230/1~/50 V/Ph/Hz
Refrigerant connection injection 1/4 inch 1/4 inch 1/4 inch 3/8 inch
Refrigerant connection, suction pipe 3/8 inch 3/8 inch 1/2 inch 5/8 inch
Condensate draining connection Ø 18 mm 18 mm 18 mm 18 mm
Refrigerant pipework, lenght/height max. 25/10 m 25/10 m 30/20 m 50/25 m
Dimensions indoor unit h/w/d 300/716/193 mm 300/804/193 mm 325/964/222 mm 342/1106/232 mm
Dimensions outdoor unit h/w/d 555/770/300 mm 555/770/300 mm 554/800/333 mm 702/845/363 mm
Weight indoor-/outdoor unit 7,5/26,4 kg 8,2/26,5 kg 10,8/37,0 kg 14,3/48,0 kg

Accessories / Spare parts

Variant
Loading ...
Loading ...
Loading ...

Downloads

Variant
Language
Pictures
REMKO RVT 264 DC AT jpg, 0.5 MB
REMKO RVT 264 DC IT jpg, 0.1 MB
Assembly drawings
REMKO RVT 264 DC AT jpg, 0.0 MB
REMKO RVT 264 DC IT jpg, 0.0 MB

Cooling load calculation for air-conditioners

The following rule of thumb applies when calculating the cooling capacity:
Approximately 30 W of cooling capacity are required per cubic meter. The cooling capacity for a room with a surface area of 28 m2 and height of 2.5 m can be calculated as follows:

28 m2 x 2,5 m x 30 W/m3 = 2.100 Watt (2,1 kW)

We recommend that you always calculate the cooling capacity for the room precisely.

Cooling load calculation Calculate required cooling capacity

Cooling load calculation