REMKO GPS SERIES Wall-mounted heating systems with modulating gas burner
![ErP-ready 2021 [Translate to Englisch:]](/fileadmin/redakteure/_processed_/b/3/csm_ErP-ready_ca275a9756.jpg)
REMKO GPS SERIES Wall-mounted heating systems with modulating gas burner
Hall heating with high energy efficiency
The REMKO series is characterised by their compact dimensions, flexible application possibilities, and particularly by their microprocessor controlled gas burner technology. A total of five unit sizes with a heating capacity from 10.1 to 73.5 kW is available. The units are suitable for both wall and ceiling mounting. A variety of exhaust gas and fresh air versions rounds out the flexible installation possibility of this series of units. Through the use of the two-stage gas burner technology, a high energy efficiency is achieved with simple technology.
- High energy efficiency with an operating efficiency up to 97% due to modulating gas burner technology
- Highly flexible applications
- Space-saving mounting on the wall or ceiling
- Rapid, cost-effective installation
- Combustion chamber in INOX steel
- No condensate formation in the heat exchanger

High energy efficiency with modulating burner technology

Microprocessor-controlled unit technology
Technical data
Variant | GPS 20 Natural gas H | GPS 20 Natural gas L | GPS 20 Propane gas | GPS 30 Natural gas H | GPS 30 Natural gas L | GPS 30 Propane gas | GPS 40 Natural gas H | GPS 40 Natural gas L | GPS 40 Propane gas | GPS 60 Natural gas H | GPS 60 Natural gas L | GPS 60 Propane gas | GPS 80 Natural gas H | GPS 80 Natural gas L | GPS 80 Propane gas |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Nominal heat load max. | 10.6 to 16.5 kW | 10.6 to 16.5 kW | 10.6 to 16.5 kW | 16.9 to 27 kW | 16.9 to 27 kW | 16.9 to 27 kW | 21.1 to 34.8 kW | 21.1 to 34.8 kW | 21.1 to 34.8 kW | 31.3 to 52.2 kW | 31.3 to 52.2 kW | 31.3 to 52.2 kW | 46.3 to 73.5 kW | 46.3 to 73.5 kW | 46.3 to 73.5 kW |
Fuel | Natural gas H | Natural gas L | Liquid gas I3P | Natural gas H | Natural gas L | Liquid gas I3P | Natural gas H | Natural gas L | Liquid gas I3P | Natural gas H | Natural gas L | Liquid gas I3P | Natural gas H | Natural gas L | Liquid gas I3P |
Exhaust gas mass flow | (EGH) 27 kg/h | (EGH) 27 kg/h | (EGH) 27 kg/h | (EGH) 45 kg/h | (EGH) 45 kg/h | (EGH) 45 kg/h | (EGH) 58 kg/h | (EGH) 58 kg/h | (EGH) 58 kg/h | (EGH) 86 kg/h | (EGH) 86 kg/h | (EGH) 86 kg/h | (EGH) 122 kg/h | (EGH) 122 kg/h | (EGH) 122 kg/h |
Power supply | 230/1~/50 | 230/1~/50 | 230/1~/50 | 230/1~/50 | 230/1~/50 | 230/1~/50 | 230/1~/50 | 230/1~/50 | 230/1~/50 | 230/1~/50 | 230/1~/50 | 230/1~/50 | 230/1~/50 | 230/1~/50 | 230/1~/50 |
Max. power consumption | 0.1 / 0.143 kW | 0.1 / 0.143 kW | 0.1 / 0.143 kW | 0.15 / 0.197 kW | 0.15 / 0.197 kW | 0.15 / 0.197 kW | 0.13 / 0.184 kW | 0.13 / 0.184 kW | 0.13 / 0.184 kW | 0.268 / 0.33 kW | 0.268 / 0.33 kW | 0.268 / 0.33 kW | 0.454 / 0.493 kW | 0.454 / 0.493 kW | 0.454 / 0.493 kW |
Nominal current consumption max. | 0.6 A | 0.6 A | 0.6 A | 0.9 A | 0.9 A | 0.9 A | 0.8 A | 0.8 A | 0.8 A | 1.4 A | 1.4 A | 1.4 A | 2.1 A | 2.1 A | 2.1 A |
Dimensions H/W/D | 690/500/795 mm | 690/500/795 mm | 690/500/795 mm | 690/500/795 mm | 690/500/795 mm | 690/500/795 mm | 690/500/985 mm | 690/500/985 mm | 690/500/985 mm | 765/500/985 mm | 765/500/985 mm | 765/500/985 mm | 765/500/1310 mm | 765/500/1310 mm | 765/500/1310 mm |
Accessories / Spare parts
Downloads
Heat requirement chart for heating systems
The diagram allows you to quickly determine the necessary heating power requirements of the hot air heating system to be used. It is based on a rough heat demand estimate for factories and similar buildings.
Heat requirement chart Determination of the necessary heating output