REMKO HTS SERIES Air/water system for heating and cooling

ARTstyle heat pumps

REMKO series will captivate you with its unique design and the whisper-quiet operation of the outdoor unit. The state-of-theart technology in the indoor unit guarantee maximum efficiency. In combination with a photovoltaic system, optimum energy consumption of the self-generated current is achieved. The cooling function is integrated by standard.

Profit from these advantages

  • Complete compact system consisting of an indoor and outdoor unit
  • Inverter-Plus technology (HTS 90/130/200/260)
  • Effective domestic water preparation
  • Integrated solar control
  • Optimised use of photovoltaic current
    Smart-Heating/Cooling
  • Speed-controlled radial fan with EC technology in outdoor unit
    ErP Ready
  • Smart-Control Touch control system
    Use in the Smart-Grid intelligent power mains is possible
  • Hermetically sound insulated indoor unit housing for the minimisation of noise emissions
  • Integrated power-controlled circulation pump with EC technology for the supply of the heating system and buffer tank
  • Integrated electronic bypass valve for guaranteeing the minimum volume flow rate (HTS 90/130/200/260)
  • Control of two mixed and one non-mixed heating circuits
  • Particularly noise-insulated scroll condenser in indoor unit
  • Intelligent, needs-based automatic defrost function
  • Noise-optimised outdoor unit
  • Switchover to night operation mode for additional reduction of noise (HTS 90/130/200/260)
  • WI-FI ready

Scope of supply

  • REMKO Smart-Control Touch - the intelligent control system
  • Indoor unit with Inverter-Plus technology
  • 1 outdoor unit (HTS 80/90/110/130)
    2 outdoor units (HTS 200/260)
  • 1 highly efficient, controlled heating circuit pump
  • Dirt filter
  • 2 shut-off valves
  • Safety group with SIV, automatic bleeding valve and pressure gauge
  • Outdoor sensor/immersion probe

Technical data

Variant HTS 80 ALU
HTS 80 CAMURA
HTS 90 ALU
HTS 90 CAMURA
HTS 110 ALU
HTS 110 CAMURA
HTS 130 ALU
HTS 130 CAMURA
HTS 200 ALU
HTS 200 CAMURA
HTS 260 ALU
HTS 260 CAMURA
SystemLuft/Wasser Luft/Wasser Luft/Wasser Luft/Wasser Luft/Wasser Luft/Wasser
Operating modeHeizen/Kühlen Heizen/Kühlen Heizen/Kühlen Heizen/Kühlen Heizen/Kühlen Heizen/Kühlen
TestingEHPA EHPA EHPA EHPA EHPA EHPA
Inverter technology- Serie - Serie Serie Serie
Preparation for domestic waterSerie Serie Serie Serie Serie Serie
Number outdoor/indoor units 1 / 1 1 / 1 1 / 1 1 / 1 2 / 1 2 / 1
Service limits, heating-20 to +42 °C -20 to +45 °C -20 to +42 °C -20 to +45 °C -20 to +45 °C -20 to +45 °C
Energy efficiency rating for heatingA++/A++ A++/A++ A++/A++ A++/A+ A++/A++ A++/A+
Rated heating capacity4.00-5.00 kW 7.00 7.00-8.00 kW 8.00 11.00 15.00
Heating capacity / COP for A7/W356.63 kW/ 4.72 7.33 kW/ 5.10 9.89 kW/ 4.78 10.31 kW/ 5.00 15.51 kW/ 5.00 20.62 kW/ 5.00
Heating capacity / COP for A2/W355.10 kW/ 3.75 5.30 kW/ 3.80 7.11 kW/ 3.80 7.41 kW/ 3.70 12.01 kW/ 3.90 17.41 kW/ 3.80
Max supply temperature, heating water heat pump60 °C63 °C60 °C63 °C63 °C63 °C
Cooling capacity / EER for A35/W7 4.5 kW/ 2.35 5.73 kW/ 2.5 6.08 kW/ 2.36 7.77 kW/ 2.3 10.4 kW/ 2.4 14.82 kW/ 2.5
Cooling capacity / EER for A35/W18+5.83 / +3.21 +6.46 / +3.3 +8.59 / +3.48 +7.57 / +3.4 +11.8 / +3.7 +15.77 / +3.8
Min. flow temperature cooling water heat pump7 °C7 °C7 °C7 °C7 °C7 °C
Refrigerant410A R 410A 410A R 410A R 410A R 410A
Basic refrigerant filling volume2.75 kg 2.75 kg 2.95 kg 2.95 kg 5.4 kg 5.4 kg
Refrigerant piping connection per outdoorunit3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8 3/8 / 5/8
Max. refrigerant pipe length per outdoorunit30 m50 m30 m50 m25 m25 m
Max. refrigerant pipe height10 m30 m10 m30 m15 m15 m
Power supply Indoorunit230/1/50 400/3~/50 230/1/50 400/3~/50 400/3~/50 400/3~/50
Power supply Outdoorunit400/3/50 230/1/50 400/3/50 230/1~/50 230/1~/50 230/1~/50
Voltage supply for electrical heating element400/3/50 400/3~/N/50 400/3/50 400/3~/N/50 400/3~/N/50 400/3~/N/50
Nominal power consumption heating for A7/W351.44 kW 1.43 kW 2.06 kW 2.08 kW 3.1 kW 4.15 kW
Rated current consumption heating for A7/W352.7 A 7.23 A 3.01 A 4.08 A 5.12 A 8.11 A
On-site fuse protection outdoor unit/indoor unit3x16 16 3x20 16 3x16 3x20
External maximum pressure loss, heating system40 / - kPa 80 / - kPa 40 / - kPa 80 / - kPa 80 / - kPa 80 / - kPa
Max. operating pressure, water3 bar3 bar3 bar30 bar3 bar3 bar
Hydraulic connection supply / return flow1 1 1 1 1 1/4 1 1/4
Sound power level indoor unit/outdoor unit 43 / 56 dB(A) 47 / 56 dB(A) 44 / 56 dB(A) 51 / 56 dB(A) 52 / 54 dB(A) 53 / 56 dB(A)
Dimensions of indoor unit h/w/d1065/650/650 mm 1065/650/650 mm 1065/650/650 mm 1065/650/650 mm 1065/650/650 mm 1065/650/650 mm


Downloads

Language
Pictures
HTS 80 Alu jpg, 915,557,000.0
HTS 80 Alu jpg, 571,865,000.0
HTS 80 Alu jpg, 841,199,000.0
HTS 80 IM jpg, 915,557,000.0
HTS B Designline ALU AM jpg, 1,257,022,000.0
Logos
HTS 80 Alu jpg, 96,321,000.0
HTS 80 Alu jpg, 68,957,000.0
HTS 80 Alu jpg, 148,393,000.0
Assembly drawings
HTS B Designline ALU AM jpg, 109,896,000.0