HTS SERIES - Bild 58466

REMKO HTS SERIES Air/water system for heating and cooling

Variant EDV-Nr. Area of use: heating
HTS 90 ALU
HTS 90 CAMURA
255095
255099
1-8 kW
HTS 130 ALU
HTS 130 CAMURA
255100
255104
8-13 kW
HTS 200 ALU
HTS 200 CAMURA
255105
255109
13-18 kW
HTS 260 ALU
HTS 260 CAMURA
255110
255114
18-23 kW

Variant

REMKO HTS SERIES

ARTstyle heat pumps with inverter technology

REMKO series HTS 90/130/200/260 will captivate you with its unique design and the whisper-quiet operation of the outdoor unit, as well as the Inverter-Plus technology in the indoor unit. Through the modulating operation, the internal heating circuit pump can directly operate the heating system. In this way, maximum efficiency and, in combination with a photovoltaic system, optimum energy consumption of the self-generated current are achieved. The cooling function is integrated by standard.

Profit from these advantages

  • Complete compact system consisting of an indoor and outdoor unit
  • Inverter-Plus technology
  • Effective domestic water preparation
  • Integrated solar control
  • Optimised use of photovoltaic current
    Smart-Heating/Cooling
  • Speed-controlled radial fan with EC technology in outdoor unit
    ErP Ready
  • Multitalented Smart-Control control system
    Use in the Smart-Grid intelligent power mains is possible
  • Hermetically sound insulated indoor unit housing for the minimisation of noise emissions
  • Integrated power-controlled circulation pump with EC technology for the supply of the heating system and buffer tank
  • Integrated electronic bypass valve for guaranteeing the minimum volume flow rate
  • Control of two mixed and one non-mixed heating circuits
  • Particularly noise-insulated scroll condenser in indoor unit
  • Intelligent, needs-based automatic defrost function
  • Noise-optimised outdoor unit
  • Switchover to night operation mode for additional reduction of noise

Scope of supply

  • REMKO Smart-Control - the intelligent control system
  • Indoor unit with Inverter-Plus technology
  • 1 outdoor unit (HTS 90/130)
    2 outdoor units (HTS 200/260)
  • 1 highly efficient, controlled heating circuit pump
  • Dirt filter
  • 2 shut-off valves and thermometer
  • Safety group with SIV, automatic bleeding valve and pressure gauge
  • Outdoor sensor/immersion probe

Technical data

Variant HTS 90 ALU
HTS 90 CAMURA
HTS 130 ALU
HTS 130 CAMURA
HTS 200 ALU
HTS 200 CAMURA
HTS 260 ALU
HTS 260 CAMURA
area of use 1-8 kW 8 - 13 kW 13 - 18 kW 18 - 23 kW
Design Singlesplit Singlesplit Singlesplit Singlesplit
function Heizen/Kühlen Heizen/Kühlen Heizen/Kühlen Heizen/Kühlen
Testing EHPA EHPA EHPA EHPA
inverter technology Serie Serie Serie Serie
system Luft/Wasser Luft/Wasser Luft/Wasser Luft/Wasser
heatpump manager Smart Control Smart Control Smart Control Smart Control
electric booster heating optional 9 kW optional 9 kW optional 9 kW optional 9 kW
Domestic water preparation Serie °C Serie °C Serie °C Serie °C
Quantity Outdoor/Indoor units 1/1 1/1 2/1 2/1
Operating limit, heating -20 bis +45 °C -20 bis +45 °C -20 bis +45 °C -20 bis +45 °C
Heating capacity min - max 1,5 - 9,5 kW 2,5-13 kW 3,0 - 18,0 kW 5,0-26,0 kW
Rated heating output 7,0 kW 8,0 kW 11,0 kW 15,0 kW
Energy efficiency rating heating A++/A++ A++/A+ A++/A++ A++/A+
Seasonal changes in space heating energy efficiency 160/131 % 158/122 % 165/131 % 164 %
Power consumption, yearly, heating 3390/4461 kWh 3931/6165 kWh 5582/7653 kWh 7579 kWh
Heating capacity / COP for A7/W35 7,33/5,1 kW 10,31/5,0 kW 15,51/5,0 kW 20,62/5,0 kW
Heating capacity / COP for A2/W35 5,30/3,8 kW 7,41/3,7 kW 12,01/3,9 kW 17,41/3,8 kW
Heating capacity / COP for A-7/W35 4,88/3,4 kW 6,76/3,3 kW 9,64/3,8 kW 9,64/3,2 kW
max.Supply temperature heating water +63 °C +63 °C +63 °C +63 °C
Operating limit, cooling +15 bis +45 °C +15 bis +45 °C +15 bis +45 °C +15 bis +45 °C
Cooling capacity min./max. 1,1 - 7,8 kW 2,3 - 11,1 kW 2,7 - 14,0 kW 4,4 - 19,1 kW
Rated cooling output 5,0 kW 7,0 kW 10,0 kW 14,0 kW
Cooling capacity / EER for A35/W7 5,73/2,5 kW 7,77/2,3 kW 10,40/2,4 kW 14,82/2,5 kW
Cooling capacity / EER for A35/W18 6,56/3,0 kW 7,85/3,4 kW 12,40/3,5 kW 16,10/3,7 kW
Cooling capacity / EER for A27/W18 6,46/3,3 kW 7,57/3,4 kW 11,80/3,7 kW 15,77/3,8 kW
min.Supply temperature cooling water +7 °C +7 °C +7 °C +7 °C
External pressure loss max. (heating system) 80 kPa 80 kPa 80 kPa 80 kPa
Refrigerant R 410A R 410A R 410A R 410A
Refriegrant charge 1,75 kg 2,95 kg 5,4 kg 5,4 kg
CO2 Equivalent 3,7 t 6,16 t 11,28 t 11,28 t
Refrigerant piping connection per outdoorunit 3/8 / 5/8 inch 3/8 / 5/8 inch 3/8 / 5/8 inch 3/8 / 5/8 inch
Max. refrigerant pipe length per outdoorunit 50 m 50 m 25 m 25 m
Max. refrigerant pipe height 30 m 30 m 15 m 15 m
Power supply Outdoorunit 230/1/50 V/Ph/Hz 230/1~/50 V/Ph/Hz 230/1~/50 V/Ph/Hz 230/1~/50 V/Ph/Hz
Power supply for electrical heating element 400/3~/N/50 V/Ph/Hz 400/3~/N/50 V/Ph/Hz 400/3~/N/50 V/Ph/Hz 400/3~/N/50 V/Ph/Hz
Power supply Indoorunit 400/3~/50 V/Ph/Hz 400/3~/50 V/Ph/Hz 400/3~/50 V/Ph/Hz 400/3~/50 V/Ph/Hz
Customer´s fuse protection (outdoor unit/Indoorunit) 16 A slow-acting 16 A slow-acting 3x16 A slow-acting 3x20 A slow-acting
max . Power consumption 2,52 kW 4,21 kW 6,39 kW 8,45 kW
max. current consumption 12,2 A 7,30 A 10,20 A 14,4 A
Rated power consumption Heating for A7/W35 1,43 kW 2,08 kW 3,10 kW 4,15 kW
Rated current consumption Heating for A7/W35 7,23 A 4,08 A 5,12 A 8,11 A
max. Airflow outdoorunit 2700 m³/h 2700 m³/h 5000 m³/h 5400 m³/h
Volumetric flow water 1,25 m³/h 1,79 m³/h 2,60 m³/h 3,50 m³/h
Max. operating pressure water 3 bar 3,0 bar 3 bar 3 bar
Hydraulic connection supply / return flow 1 inch 1 inch 1 1/4 inch 1 1/4 inch
Soundpowerlevel Indoorunit/outdoor unit 47/56 dB(A) 51/56 dB(A) 52/54 dB(A) 53/56 dB(A)
Soundpressure LpA 1m Indoorunit/outdoor unit 25/34 dB(A) 29/34 dB(A) 29/32 dB(A) 30/34 dB(A)
Soundpowerlevel Indoorunit/outdoor unit decrease mode 44/43 dB(A) 48/43 dB(A) 50/41 dB(A) 51/43 dB(A)
Soundpressure LpA 1m Indoorunit/outdoor unit decrease mode 22/21 dB(A) 27/21 dB(A) 28/19 dB(A) 29/21 dB(A)
Dimensions indoor unit h/w/d 1065/650/650 mm 1065/650/650 mm 1065/650/650 mm 1065/650/650 mm
Dimensions outdoor unit 1020/630 mm 1020/630 mm 1020/630 mm 1020/630 mm
Weight indoor unit / outdoor unit 170/120 kg 180/123 kg 196/120 kg 200/120 kg
standard color outdoorunit Alu eloxiert Alu eloxiert Alu eloxiert Alu eloxiert
standard color indoorunit RAL 9006 RAL 9006 RAL 9006 RAL 9006

Accessories / Spare parts

Variant
Loading ...
Loading ...
Loading ...
Loading ...

Downloads

Variant
Language
Pictures
HTS 90 IM jpg, 1.0 MB
HTS B Designline ALU AM jpg, 1.3 MB
Assembly drawings
HTS 90 IM jpg, 0.1 MB
HTS B Designline ALU AM jpg, 0.1 MB

Hydraulic configurator Hydraulic schemes for heat pumps

Hydraulic configurator