REMKO WSP DUO SERIES Brine/water system for cooling and heating

WSP DUO SERIES - Bild 84650 WSP DUO SERIES - Bild 84651 WSP DUO SERIES - Bild 84652 WSP DUO SERIES - Bild 84653 [Translate to Englisch:]
Variant
EDV-Nr.
Area of use: heating
REMKO WSP DUO SERIES Brine/water system for heating and cooling
Heat and air-condition reliably with geothermal energy

With the brine heat pump of the WSP Duo series, REMKO offers a compact system by means of which the use of geothermal heat can be implemented for effective heating, domestic water heating and optional, passive cooling. Geothermal heat can be extracted by deep drilling or surface collectors. The system permits a high heating comfort without operating noises outdoors. Due to high inlet temperatures up to 60 °C, the WSP brine heat pump can also be optimally used for energetic renovation in old buildings. Due to the cascade connection, high heating capacities can be implemented.

Profit from these advantages
  • No outdoor operating noises
  • High inlet temperatures up to 60°C
  • Effective heating, preparation for domestic water and passive cooling optionally available
  • Use of geothermal energy by means of deep drilling or surface collectors
  • Remote access possible through the REMKO Smart Web Portal
  • SmartServ 9 kW per heat pump for emergency heating operation optional
  • Integrated solar control
  • Optimised use of photovoltaic current
    Smart Heating / Cooling
  • Control of 4 mixed and 1 non-mixed heating circuits
  • Smart-Control Touch
    Use in the Smart-Grid intelligent power mains is also possible
  • Especially noise-insulated scroll condenser in indoor unit
  • Hermetically noise-insulated indoor unit housing for the minimisation of power losses and noise emissions
  • Integrated power-controlled circulation pumps with EC technology for the supply of the heating system and heat source
  • Smooth operation through cascade connection
  • WI-FI ready
Scope of supply
  • REMKO Smart-Control Touch - the intelligent control system
  • 1 highly efficient, controlled heating circuit pump (per heat pump)
  • 1 highly efficient, controlled heat source pump (per heat pump)
  • 4 shut-off valves (per heat pump)
  • Dirt filter for heating circuit and heat source (per heat pump)
  • 2 safety groups with SIV, automatic bleeding valve  and pressure gauge
  • Outdoor probe/immersion probe

Technische Daten
VariantWSP 140 DuoWSP 180 Duo
VersionMonobloc Kaskade Monobloc Kaskade
SystemBrine-to-water Brine-to-water
Operating modeHeizen/WW Heizen/WW
TestingEHPA EHPA
Preparation for domestic waterSerie Serie
Number of indoor units2 2
Nominal heating capacity22.00 34.00
Heating capacity/COP for B0/W35+21.6 / +4.88 +34.4 / +5.15
Heating capacity/COP for B0/W55+18.4 / +2.75 +30 / +2.8
Heat source operating limit, heating-10 to +25 °C -10 to +25 °C
Max supply temperature, heating water, heat pump60 °C60 °C
Application limit, heat source, passive cooling+2 to +20 °C +2 to +20 °C
Min. flow temperature cooling water heat pump15 °C15 °C
RefrigerantR410A R410A
Basic refrigerant filling volume2x2.6 kg 2x2.8 kg
Voltage supply for heat pump400/3/N/50 400/3/N/50
Smart-Control power supply230/1/N/50 230/1/N/50
Voltage supply for electrical heating element400/3/N/50 400/3/N/50
Nominal power consumption, heating, for B0/W354.42 6.66
Nominal power consumption heating for B0/W357.2 A10.8 A
Nominal power consumption source pump100 W110 W
On-site fuse protection, heat pump, compressor2x 3x16 2x 3x20
Nominal volume flow rate heating B0/W353.2 m³/h5 m³/h
Nominal volume flow rate heat source B0/W354.2 m³/h6.6 m³/h
Max. operating pressure, water3 bar3 bar
Hydraulic connection heating system/heat source1 1/4 / 1 1/4 1 1/4 / 1 1/4
Pipeline diameter to be used on site, Cu pipe42 mm42 mm
Sound power level LwA heat pump45 dB(A)46 dB(A)
Dimensions of heat pump h/w/d1065/650/650 1065/650/650
Weight, heat pump200 kg210 kg

Downloads
Language
Pictures
REMKO WSP 140 Duo jpg, 233,731,000.0