REMKO LWM Cologne








REMKO LWM SERIES
Heat pump package type Cologne
This heat pump package is designed for users who want heating and cooling first and foremost. The additional KPS 301 buffer tank is used for the hydraulic decoupling of large medium flow rates. A cooling function for the summer can also be activated, if necessary. Preparation for domestic water takes place separately. With this heat pump package, both monoenergetic and bivalently alternating systems can be accommodated.
The separate pump assemblies HGU/HGM (can be ordered separately) for the heating circuits are equipped with a high-efficiency pump regulated in a needs-based manner.
Package consisting of:
- Monobloc heat pump
- Steam-diffusion-proof buffer tank for cooling and hot water KPS 301 (300 l)
- Smart-Control Touch, surface-mounted version

Smart-Control Touch, surface-mounted version
Technical data
Variant | LWM 80 ALU LWM 80 GRAPHIT LWM 80 CAMURA | LWM 110 ALU LWM 110 GRAPHIT LWM 110 CAMURA | LWM 150 ALU LWM 150 GRAPHIT LWM 150 CAMURA | LWM 110 Duo ALU LWM 110 Duo GRAPHIT LWM 110 Duo CAMURA | LWM 150 Duo ALU LWM 150 Duo GRAPHIT LWM 150 Duo CAMURA |
---|---|---|---|---|---|
System | Air/water | Air/water | Air/water | Air/water | Air/water |
Operating mode | Heating/cooling | Heating/cooling | Heating/cooling | Heating/cooling | Heating/cooling |
Testing | EHPA | EHPA | EHPA | EHPA | EHPA |
Inverter technology | Series | Series | Series | Series | Series |
Number of outdoor/indoor units | 1 / - | 1 / - | 1 / - | 2 / - | 2 / - |
Application limit, heating | -23 to +37 °C | +37 to - °C | -23 to +37 °C | -23 to +37 °C | -23 to +37 °C |
Nominal heating capacity | 6.00 | 8.00 | 10.00 | 16.00 | 20.00 |
Heating capacity/COP for A7/W35 | 6.25 kW/ 5.10 | 8.04 kW/ 5.02 | 10.29 kW/ 5.03 | 16.08 kW/ 5.02 | 20.58 kW/ 5.03 |
Heating capacity/COP for A2/W35 | 4.33 kW/ 4.09 | 6.35 kW/ 4.04 | 8.33 kW/ 4.11 | 12.70 kW/ 4.04 | 16.66 kW/ 4.11 |
Cooling capacity/EER for A35/W7 | 4.9 kW/ 2.81 | 7.63 kW/ 2.73 | 12.2 kW/ 2.65 | 15.26 kW/ 2.73 | 24.4 kW/ 2.65 |
Cooling capacity/EER for A35/W18 | 5.8 kW/ 3.92 | 10.71 kW/ 4 | 18.2 kW/ 4.11 | 21.42 kW/ 4 | 36.4 kW/ 4.11 |
Refrigerant | R454B | R454B | R454B | 454B | 454B |
Basic refrigerant filling volume | 1.1 kg | 1.3 kg | 1.6 kg | 2x 1.3 kg | 2x 1.6 kg |
Power supply outdoor unit | 230/1~/50 | 400/3~/50 | 400/3~/50 | 2x 400/3~/50 | 2x 400/3~/50 |
Voltage supply for electrical heating element | 400/3~/50 | 400/3~/50 | 400/3~/50 | 2x 400/3~/50 | 2x 400/3~/50 |
Nominal power consumption heating for A7/W35 | 1.22 kW | 1.6 kW | 2.04 kW | 2x1.6 kW | 2x2.04 kW |
Nominal current consumption heating for A7/W35 | 5.3 A | 2.57 A | 3.27 A | 2x2.57 A | 2x3.27 A |
On-site fuse protection outdoor unit/indoor unit | 16 | 3x 16 | 3x 16 | 2x 3x 16 | 2x 3x 16 |
External maximum pressure loss, heating system | 60 / - kPa | 50 / - kPa | 40 / - kPa | 70 / - kPa | 60 / - kPa |
Hydraulic connection supply/return flow | 11/4 | 11/4 | 11/4 | 1 1/4 | 1 1/4 |
Sound power level indoor unit/outdoor unit | - / 54 dB(A) | - / 56 dB(A) | - / 58 dB(A) | - / 56 dB(A) | - / 58 dB(A) |
Preparation for domestic water | Series | Series |