REMKO LWM Stuttgart








REMKO LWM SERIES
Heat pump package type Stuttgart
If the heat pump is intended to serve as a sole heat generator, this heat pump package is the ideal solution. In connection with underfloor heating, this unit is perfectly suited for new buildings. In addition to the heating function, a cooling function can be provided when necessary. In this package, the preparation for domestic water takes place in an enamelled, 300-litre domestic water tank integrated into the indoor unit. Through the compact design, installation expenses are extremely low. Smart-Control and the switchover and bypass valves are already installed in the indoor module and electrically connected. This saves costs and minimizes the installation time.
Package consisting of:
- Monobloc heat pump
- Indoor unit with integrated 300 litre domestic water tank
- Built-in electrically controlled bypass valve
- Built-in Smart-Control Touch
- Built-in 3-way changeover valve
Technical data
Variant | LWM 80 ALU LWM 80 GRAPHIT LWM 80 CAMURA | LWM 110 ALU LWM 110 GRAPHIT LWM 110 CAMURA | LWM 150 ALU LWM 150 GRAPHIT LWM 150 CAMURA |
---|---|---|---|
System | Air/water | Air/water | Air/water |
Operating mode | Heating/cooling/hot water | Heating/cooling/hot water | Heating/cooling/hot water |
Inverter technology | Yes | Yes | Yes |
Preparation for domestic water | Series | Series | Series |
Number of outdoor/indoor units | 1 / 1 | 1 / 1 | 1 / 1 |
Application limit, heating | -23 to +37 °C | -23 to +37 °C | -23 to +37 °C |
Nominal heating capacity | 6.00 | 8.00 | 10.00 |
Heating capacity/COP for A7/W35 | 6.25 kW/ 5.10 | 8.04 kW/ 5.02 | 10.29 kW/ 5.03 |
Heating capacity/COP for A2/W35 | 4.33 kW/ 4.09 | 6.35 kW/ 4.04 | 8.33 kW/ 4.11 |
Cooling capacity/EER for A35/W7 | 4.9 kW/ 2.81 | 7.63 kW/ 2.73 | 12.2 kW/ 2.65 |
Cooling capacity/EER for A35/W18 | 5.8 kW/ 3.92 | 10.71 kW/ 4 | 18.2 kW/ 4.11 |
Refrigerant | R454B | R454B | R454B |
Basic refrigerant filling volume | 1.1 kg | 1.3 kg | 1.6 kg |
Power supply outdoor unit | 230/1~/50 | 400/3~/50 | 400/3~/50 |
Voltage supply for electrical heating element | 400/3~/50 | 400/3~/50 | 400/3~/50 |
Nominal power consumption heating for A7/W35 | 1.22 kW | 1.6 kW | 2.04 kW |
Nominal current consumption heating for A7/W35 | 5.3 A | 2.57 A | 3.27 A |
On-site fuse protection outdoor unit/indoor unit | 16 | 3x 16 | 3x 16 |
External maximum pressure loss, heating system | 60 / - kPa | 50 / - kPa | 40 / - kPa |
Hydraulic connection supply/return flow | 11/4 | 11/4 | 11/4 |
Sound power level indoor unit/outdoor unit | - / 54 dB(A) | - / 56 dB(A) | - / 58 dB(A) |
Dimensions of indoor unit h/w/d | 1420/650/960 mm | 1420/650/960 mm | 1420/650/960 mm |