RVD SERIES - Bild 56867 RVD SERIES - Bild 62365 RVD SERIES - Bild 56869

REMKO RVD SERIES Ceiling cassettes for cooling and heating

Powerful and practically invisible

Due to its flat design and its whisper-quiet operation, the RVD series ceiling cassettes are ideal for use in the office. Thanks to the latest inverter technology from REMKO, the ceiling cassettes operate particularly reliably and efficiently.

  • Compact dimensions in European grid format up to RVD 525 DC
  • Low-noise unit operation 
  • Removable air filter
  • Air discharge with swing function
  • Programmable 24-hour timer function
  • Alarm contact/contact for ext. release
  • Built-in condensate pump (maximum pump head of 500 mm)
  • "Follow me" function for temperature reconciliation between unit and remote controller
  • The outdoor units are filled with R32 refrigerant at the factory
    (line length up to 5 m)

Technical data

VariantRVD 355 DCRVD 525 DCRVD 685 DCRVD 1055 DC
Cooling capacity3,5 (1,5-5,3) kW5,3 (2,9-5,7) kW7,0 (3,2-8,2) kW10,5 (4,0-12,0) kW
Energy efficiency class (cooling)A++ A++ A++ A++
Energy efficiency ratio SEER7,8 6,1 6,1 6,1
Power consumption cooling, annual, QCE157 kWh304 kWh402 kWh602 kWh
Heating capacity3,1 (1,0-5,6) kW4,2 (2,4-6,1) kW5,4 (2,4-8,7) kW8,1 (2,6-13,2) kW
Energy efficiency class (heating)A++ A+ A+ A++
Energy efficiency ratio SCOP4,6 4,0 4,0 A+
Power consumption heating, annual, QHE959 kWh1435 kWh1890 kWh2835 kWh
RefrigerantR32 R32 R32 R32
GWP value675 675 675 675
Refrigerant, basic amount0,87 kg1,15 kg1,5 kg2,4 kg
CO2 Equivalent0,5873 t0,776 t1,010 t1,62 t
Total power input0,85 kW1,63 kW2,19 kW3,95 kW
Power input3,8 A7,2 A9,5 A6,6 A
Operating range (room size)110 m³160 m³230 m³320 m³
Operating range, indoor unit+17 bis +30 °C+17 bis +30 °C+17 bis +30 °C+17 bis +30 °C
Operating range, cooling+5 bis +50 °C+5 bis +50 °C+5 bis +50 °C+5 bis +50 °C
Operating range, heating+5 bis +24 °C+5 bis +24 °C+5 bis +24 °C+5 bis +24 °C
Fan stages4 4 4 4
Nominal air volume per stage416/504/617 m³/h540/625/750 m³/h1032/1200/1378 m³/h1438/1620/1775 m³/h
Sound pressure level per stage, indoor unit33/36/41 dB(A)36/39/43 dB(A)36/39/43 dB(A)41/47/51 dB(A)
Soundpower indoor unit max51 dB(A)56 dB(A)59 dB(A)62 dB(A)
Soundpower outdoor unit max63 dB(A)63 dB(A)64 dB(A)68 dB(A)
Power supply230/1~/50 V/Ph/Hz230/1~/50 V/Ph/Hz230/1~/50 V/Ph/Hz400/3~/50 V/Ph/Hz
Refrigerant connection injection1/4 inch1/4 inch3/8 inch3/8 inch
Refrigerant connection, suction pipe3/8 inch1/2 inch5/8 inch5/8 inch
Condensate draining connection Ø25 mm25 mm32 mm32 mm
Refrigerant pipework, lenght/height max.25 m30/20 m50 m65 m
Refrigerant pipework, length/height max. per cycle10 m25 m30 m
Dimensions indoor unit h/w/d570/570/260 mm570/570/260 mm840/840/245 mm840/840/245 mm
Dimensions outdoor unit h/w/d554/800/333 mm554/800/333 mm702/845/363 mm810/946/410 mm
Weight indoor-/outdoor unit18,7/34,7 kg16,2/35,6 kg28,0/49,4 kg27,5/81,5 kg

Accessories / Spare parts

Loading ...
Loading ...
Loading ...

Downloads

Language
Pictures
REMKO RVD 355 DC jpg, 324,332,000.0
REMKO RVD 355 DC jpg, 365,662,000.0
REMKO RVD 355 DC jpg, 644,408,000.0
REMKO RVD 355 DC AT jpg, 324,332,000.0
REMKO RVD 355 DC IT jpg, 365,662,000.0
Assembly drawings
REMKO RVD 355 DC AT jpg, 236,174,000.0
REMKO RVD 355 DC IT jpg, 194,416,000.0

Cooling load calculation for air-conditioners

The following rule of thumb applies when calculating the cooling capacity:
Approximately 30 W of cooling capacity are required per cubic meter. The cooling capacity for a room with a surface area of 28 m2 and height of 2.5 m can be calculated as follows:

28 m2 x 2,5 m x 30 W/m3 = 2.100 Watt (2,1 kW)

We recommend that you always calculate the cooling capacity for the room precisely.

Cooling load calculation Calculate required cooling capacity