REMKO RVD SERIES Ceiling cassettes for cooling and heating

Powerful and practically invisible

Due to its flat design and its whisper-quiet operation, the RVD series ceiling cassettes are ideal for use in the office. Thanks to the latest inverter technology from REMKO, the ceiling cassettes operate particularly reliably and efficiently.

  • Compact dimensions in European grid format up to RVD 525 DC
  • Low-noise unit operation 
  • Removable air filter
  • Air discharge with swing function
  • Programmable 24-hour timer function
  • Alarm contact/contact for ext. release
  • Built-in condensate pump (maximum pump head of 500 mm)
  • "Follow me" function for temperature reconciliation between unit and remote controller
  • The outdoor units are filled with R32 refrigerant at the factory
    (line length up to 5 m)

Technical data

VariantRVD 355 DCRVD 525 DCRVD 685 DCRVD 1055 DC
Cooling capacity3.50 (1.50-5.30) kW 5.30 (2.90-5.70) kW 7.00 (3.20-8.20) kW 10.50 (4.00-12.00) kW
Energy efficiency rating for coolingA++ A++ A++ A++
Heating capacity3.10 (1.00-5.60) kW 4.20 (2.40-6.10) kW 5.40 (2.40-8.70) kW 8.10 (2.60-13.20) kW
Energy efficiency rating for heatingA++ A+ A+ A++
RefrigerantR32 R32 R32 R32
Usage area (room size) approx. 110 160 230 320
Operating range, indoor unit17-30 °C 17-30 °C 17-30 °C 17-30 °C
Working range, cooling+5 to +50 °C +5 to +50 °C +5 to +50 °C +5 to +50 °C
Operating range heating+5 to +24 °C +5 to +24 °C +5 to +24 °C +5 to +24 °C
Air flow rate speed settings416/504/617 m³/h 540/625/750 m³/h 1032/1200/1378 m³/h 1438/1620/1775 m³/h
Sound pressure level per speed setting, indoor unit33/36/41/-/- dB(A) 36/39/43/-/- dB(A) 36/39/43/-/- dB(A) 41/47/51/-/- dB(A)
Sound power max. outdoor unit 63 dB(A) 63 dB(A) 64 dB(A) 68 dB(A)
Power supply230/1~/50 230/1~/50 230/1~/50 400/3~/50
Refrigerant connection, injection line1/4 1/4 3/8 3/8
Refrigerant connection, suction pipe3/8 1/2 5/8 5/8
Refrigerant line length/height max.25.0 / - m 30.0 / 20.0 m 50.0 / - m 65.0 / - m
Dimensions of indoor unit h/w/d570/570/260 mm 570/570/260 mm 840/840/245 mm 840/840/245 mm
Dimensions outdoor unit H/W/D554/800/333 mm 554/800/333 mm 702/845/363 mm 810/946/410 mm
Weight indoor/outdoor unit 18.7 / 34.7 kg 16.2 / 35.6 kg 28.0 / 49.4 kg 27.5 / 81.5 kg


Downloads

Language
Pictures
REMKO RVD 355 DC jpg, 324,332,000.0
REMKO RVD 355 DC jpg, 365,662,000.0
REMKO RVD 355 DC jpg, 644,408,000.0
REMKO RVD 355 DC AT jpg, 324,332,000.0
REMKO RVD 355 DC IT jpg, 365,662,000.0
Geräteblende jpg, 2,527,062,000.0
Assembly drawings
REMKO RVD 355 DC AT jpg, 236,174,000.0
REMKO RVD 355 DC IT jpg, 194,416,000.0

Cooling load calculation for air-conditioners

The following rule of thumb applies when calculating the cooling capacity:
Approximately 30 W of cooling capacity are required per cubic meter. The cooling capacity for a room with a surface area of 28 m2 and height of 2.5 m can be calculated as follows:

28 m2 x 2,5 m x 30 W/m3 = 2.100 Watt (2,1 kW)

We recommend that you always calculate the cooling capacity for the room precisely.

Cooling load calculation Calculate required cooling capacity

Cooling load calculation