REMKO PWN H SERIES Hot water heating systems in low-temperature design with EC fan
REMKO PWN H SERIES Hot water heaters in low-temperature design with EC fan for heating
The efficient heating system for warehouses and supermarkets
Their flat design and variable technology allows their subtle application, both in low-ceilinged and high-ceilinged rooms. The individually adjustable fins in the upper and lower parts of the housing allow optimal air distribution and thus provide a comfortable room climate. Their use in showrooms or other customer areas is possible thanks to their low sound pressure levels and their fine design. Ease of service and a simple, uncomplicated assembly are the characteristic features of these units. The media connections and the mains cabling can be installed out of sight in the false ceiling. The elegant plastic housing can easily be removed from its bearing elements thanks to the rapid release couplings. PWL H series units are fitted as standard with a high-performance condensate pump.
- Quiet operation
- Installation-friendly construction
- Service-friendly
- Universal use
- Self-extinguishing plastic housing, fire class V-0

Pivotable 3D mpunting system for optimum air distribution
Technical data
Variant | PWN 35-1 H | PWN 45-2 H | PWN 75-3 H | PWN 95-2 H | PWN 105-3 H |
---|---|---|---|---|---|
Heating capacity at 70/50 and 15°C air intake | +9.7 / - kW | +19 / - kW | +33.9 / - kW | +54.9 / - kW | +69.4 / - kW |
Heating capacity at 55/45 and 15°C air intake | +8.1 / - kW | +15.2 / - kW | +27 / - kW | +44.1 / - kW | +55.3 / - kW |
Throw | 15.4 m | 13.9 m | 21.2 m | 23.6 m | 22.3 m |
Max. operating pressure | 16 bar | 16 bar | 16 bar | 16 bar | 16 bar |
Nominal flow rate, heating medium | 0.43 / - / - | 0.83 / - / - | 1.49 / - / - | 2.41 / - / - | 3.05 / - / - |
Nominal flow rate, coolant | 0.46 / - / - | 0.81 / - / - | 1.47 / - / - | 2.69 / - / - | 2.99 / - / - |
Nominal pressure drop, internal heating | 2.4 / - / - | 5.7 / - / - | 11.8 / - / - | 12.3 / - / - | 9.4 / - / - |
Nominal pressure drop, internal, cooling | 2.8 / - / - | 5.5 / - / - | 14.5 / - / - | 19.2 / - / - | 11.5 / - / - |
Power supply | 230/1~/50 | 230/1~/50 | 230/1~/50 | 230/1~/50 | 230/50 |
Max. power consumption | 0.108 kW | 0.111 kW | 0.315 kW | 0.635 kW | 0.635 kW |
Nominal current consumption max. | 0.77 A | 0.83 A | 2.1 A | 4.24 A | 4.16 A |
Sound pressure level at 1.5m distance | +29 to +64 | +29 to +64 | +32 to +67 | +37 to +71 | +35 to +70 |
Dimensions H/W/D | 730/765/595 mm | 730/765/595 mm | 730/765/595 mm | 730/1390/595 mm | 730/1390/595 mm |
Accessories / Spare parts
Downloads
Heat requirement chart for heating systems
The diagram allows you to quickly determine the necessary heating power requirements of the hot air heating system to be used. It is based on a rough heat demand estimate for factories and similar buildings.
Heat requirement chart Determination of the necessary heating output