WKF NEO COMPACT SERIES - Bild 59151 WKF NEO COMPACT SERIES - Bild 62261 WKF NEO COMPACT SERIES - Bild 59152 WKF NEO COMPACT SERIES - Bild 59153

REMKO WKF NEO COMPACT SERIES Air/water system for heating and cooling

Variant EDV-Nr. Area of use: heating
WKF 70 NEO com. (EWS 200-E)
WKF 70 NEO com. S-Line (EWS 200-E)
WKF 70 NEO com. (EWS 301-E)
WKF 70 NEO com. S-Line (EWS 301-E)
258070
258072
258080
258082
2-7 kW
WKF 120 NEO com. (EWS 200-E)
WKF 120 NEO com. S-Line (EWS 200-E)
WKF 120 NEO com. (EWS-301-E)
WKF 120 NEO com. S-Line (EWS 301-E)
258120
258122
258130
258132
7-12 kW
WKF 180 NEO com. (EWS 200-E)
WKF 180 NEO com. S-Line (EWS 200-E)
WKF 180 NEO com. (EWS 301-E)
WKF 180 NEO com. S-Line (EWS 301-E)
258180
258182
258190
258192
12-18 kW

Variant

REMKO WKF NEO COMPACT SERIES

The compact class saves space and installation effort

The WKF NEO compact series does not require a large mounting area due to its compact construction and integrated components. In connection with underfloor heating, this unit is perfectly suited for new buildings. This construction saves space in the mounting area. The costs for installation are strongly reduced by the high percentage of premounted components.

Profit from these advantages

  • Low spatial requirements in utility room
  • Low investment costs
  • Flow temperatures up to 55 °C
  • Power-modulated operation due to modern inverter mode
  • Low operating costs due to high COP value
  • Ready for connection of solar system to drinking water supply
  • Night operation to reduce noise
  • Mounting-friendly installation, all connections at the top
  • High hot water comfort through integrated, enamelled domestic water tank with a volume of 200 or 300 litres
  • Smart-Control intelligent control system – use in intelligent Smart-Grid power mains possible
  • Integrated heating circuit pump for the supply of the heating system
  • Integrated electronic bypass valve for guaranteeing the minimum volume flow rate
  • Intelligent thawing logic circuit
  • Monoenergetic operation through REMKO Smart-Serv
  • Chimney sweep function
  • Wi-Fi ready

Scope of supply

  • REMKO Smart-Control Touch - the intelligent control system
  • Indoor unit with highly-efficient domestic water tank
  • Outdoor unit with inverter technology
  • Highly efficient, controlled heating circuit pump
  • Outdoor probe/immersion probe
  • Smart-Serv built-in heating rod 6 kW
  • Built-in industrial water set, incl. 3-way switchover valve
  • Built-in dirt filter 1"
  • Built-in electrically controlled bypass mixer
  • Prepared (flange) for solar domestic water heating

Technical data

Variant WKF 70 NEO com. (EWS 200-E)
WKF 70 NEO com. S-Line (EWS 200-E)
WKF 70 NEO com. (EWS 301-E)
WKF 70 NEO com. S-Line (EWS 301-E)
WKF 120 NEO com. (EWS 200-E)
WKF 120 NEO com. S-Line (EWS 200-E)
WKF 120 NEO com. (EWS-301-E)
WKF 120 NEO com. S-Line (EWS 301-E)
WKF 180 NEO com. (EWS 200-E)
WKF 180 NEO com. S-Line (EWS 200-E)
WKF 180 NEO com. (EWS 301-E)
WKF 180 NEO com. S-Line (EWS 301-E)
area of use 2-7 kW 7 - 12 kW 12-18 kW
Design Singlesplit Singlesplit Singlesplit
function Heizen/Kühlen Heizen/Kühlen Heizen/Kühlen
Testing EHPA EHPA EHPA
inverter technology Serie Serie Serie
system Luft/Wasser Luft/Wasser Luft/Wasser
heatpump manager Smart Control Touch Smart Control Touch Smart Control Touch
electric booster heating Serie 6 kW Serie 6 kW Serie 6 kW
Domestic water preparation Serie °C Serie °C Serie °C
DHW storage tank 200 l 200 l 200 l
Quantity Outdoor/Indoor units 1/1 1/1 1/1
Operating limit, heating -20 bis +35 °C -20 bis +35 °C -20 bis +35 °C
Heating capacity min - max 0,9 - 6,0 kW 2,5-12,5 kW 3,1-17,7 kW
Rated heating output 5,0/6,0 kW 10,0 kW 14,0 kW
Energy efficiency rating heating A++ A++ A++
Seasonal changes in space heating energy efficiency 132/108 % 136/104 % 134/105 %
Power consumption, yearly, heating 2808/3705 kWh 5514/6610 kWh 7860/9098 kWh
Heating capacity / COP for A7/W35 5,46/4,62 kW 9,86/4,4 kW 14,02/4,5 kW
Heating capacity / COP for A2/W35 4,61/3,50 kW 6,95/3,6 kW 9,32/3,53 kW
max.Supply temperature heating water 55 °C 55 °C 55 °C
Operating limit, cooling +15 bis +45 °C +15 bis +45 °C +15 bis +45 °C
Cooling capacity min./max. 1,33/5,30 kW 3,3-9,1 kW 5,5-14,0 kW
Rated cooling output 5,0 kW 6,79 kW 12,20 kW
Cooling capacity / EER for A35/W7 4,9/2,8 kW 6,79/2,3 kW 12,20/2,6 kW
Cooling capacity / EER for A35/W18 6,7/3,6 kW 5,30/3,7 kW 12,77/3,8 kW
Cooling capacity / EER for A27/W18 6,8/3,9 kW 9,46/3,6 kW
min.Supply temperature cooling water +7 °C +7 °C +7 °C
External pressure loss max. (heating system) 80 kPa 80 kPa 80 kPa
Refrigerant R 410A R 410A R 410A
Refriegrant charge 1,2 kg 2,0 kg 2,85 kg
CO2 Equivalent 2,5 t 4,18 t 5,95 t
Refrigerant piping connection per outdoorunit 3/8/5/8 inch 3/8/5/8 inch 3/8 / 5/8 inch
Max. refrigerant pipe length per outdoorunit 30 m 50 m 75 m
Max. refrigerant pipe height 20 m 30 m 30 m
Power supply Outdoorunit 230/1~/50 V/Ph/Hz 230/1~/50 V/Ph/Hz 400/3~/50 V/Ph/Hz
Power supply for electrical heating element 400/3~/50 V/Ph/Hz 400/3~/50 V/Ph/Hz 400/3~/N/50 V/Ph/Hz
Power supply Indoorunit 230/1~/50 V/Ph/Hz 230/1~/50 V/Ph/Hz 230/1~/50 V/Ph/Hz
Customer´s fuse protection (outdoor unit/Indoorunit) 25/10 A slow-acting 20/10 A slow-acting 3x16A / 10 A slow-acting
max . Power consumption 3,50 kW 4,00 kW 4,5 kW
max. current consumption 15,0 A 15,28 A 7,20 A
Rated power consumption Heating for A7/W35 1,18 kW 1,70 kW 3,09 kW
Rated current consumption Heating for A7/W35 5,19 A 10,44 A 5,02 A
max. Airflow outdoorunit 2200 m³/h 3700 m³/h 5400 m³/h
Volumetric flow water 0,95 m³/h 1,70 m³/h 2,4 m³/h
Max. operating pressure water 3,0 bar 3,0 bar 3,0 bar
Hydraulic connection supply / return flow 1 1/4 AG inch 1 1/4 AG inch 1 1/4 AG inch
Soundpowerlevel Indoorunit/outdoor unit -/63,2 dB(A) -/67,9 dB(A) -/68,3 dB(A)
Soundpressure LpA 1m Indoorunit/outdoor unit -/41,2 dB(A) -/42,2 dB(A) -/42,4 dB(A)
Soundpowerlevel Indoorunit/outdoor unit decrease mode -/60,2 dB(A) -/64,9 dB(A) -/64,3 dB(A)
Soundpressure LpA 1m Indoorunit/outdoor unit decrease mode 38,0 dB(A) -/38,9 dB(A) -/39,3 dB(A)
Dimensions indoor unit h/w/d 1350/555/850 mm 1350/555/850 mm 1350/555/850 mm
Dimensions outdoor unit h/w/d 640/880/310 mm 1010/940/330 mm 1430/940/330 mm
Weight indoor unit / outdoor unit 131/50 kg 133/74 kg 135/100 kg
standard color outdoorunit grauweiß grauweiß grauweiß
standard color indoorunit silber/schwarz silber/schwarz silber/schwarz
Heating capacity / COP for A-7/W35 6,14/2,9 kW 8,20/2,87 kW

Accessories / Spare parts

Variant
Loading ...
Loading ...
Loading ...

Downloads

Variant
Language
Pictures
REMKO WKF 70 AM jpg, 1.1 MB
WKF 70 NEO compact IM mit jpg, 1.1 MB
Assembly drawings
REMKO WKF 70 AM jpg, 0.1 MB

Hydraulic configurator Hydraulic schemes for heat pumps

Hydraulic configurator