REMKO KWD SERIES Ceiling cassetttes as 2-pipe system with 5-speed fan

Variant EDV-Nr. Cooling capacity
KWD 25 1611860 2,7 kW
KWD 35 1611862 3,3 kW
KWD 45 1611864 4,3 kW
KWD 55 1611866 5,4 kW
KWD 70 1611868 7,1 kW
KWD 85 1611870 8,1 kW
KWD 100 1611872 9,4 kW

Variant

REMKO KWD SERIES Ceiling cassetttes as 2-pipe system with 5-speed fan

Ceiling cassettes in compact European standard grid format

The small design height of the ceiling-mounted cassettes of 258 and 298 mm allows installation in almost every false ceiling. The distribution of air to all four sides ensures even air distribution. The copper-aluminium round heat exchangers are designed for medium temperatures of up to 70°C.

The 5-speed radial fan allows the optimal adaptation of the air flow rate to prevailing conditions. Ceiling-mounted cassettes are fitted as standard with an internal condensate pump. Optionally, fresh air can be blown in or adjoining rooms can also be cooled.

  • An elegant solution for ceiling installation
  • Compact dimensions in standard European grid format
  • Low-noise unit operation
  • Service-friendly unit structure
  • Low construction height
  • Silent and Turbo modes
  • With infrared remote control
  • Programmable 24-hour timer function
  • Air outlet with possible swing function
  • 5 fan speeds
  • Installed condensate pump (up to 1000 mmWS)

Regulation

In KWD 25 to KWD 100 series units, the cooling, heating, ventilation or dehumidification modes of the ceiling cassettes can be controlled automatically or manually by the operator using an infrared remote control. It is also possible to set the desired temperature, time and switch-on or switch-off time easily with the press of a button. When using multiple ceiling cassettes within a room or building, a single infrared remote control within an internal network can be used to control all of the units. With a cabled remote control within an internal network, each individual ceiling cassette can be individually addressed and programmed. Medium output can be controlled using the optional three-way valve assembly or by a valve assembly fitted to the equipment.


Technical data

VariantKWD 25KWD 35KWD 45KWD 55KWD 70KWD 85KWD 100
Cooling capacity2,7 kW3,3 kW4,3 kW5,4 kW7,1 kW8,1 kW9,4 kW
Heating capacity3,5 kW4,3 kW5,6 kW6,9 kW9,2 kW10,5 kW11,0 kW
Nominal air volume per stage375/400/420/445/490 m³/h395/420/440/490/520 m³/h455/500/520/565/650 m³/h550/620/665/740/885 m³/h620/700/830/970/1030 m³/h900/960/1040/1240/13 m³/h970/1020/1140/1260/1 m³/h
Sound pressure level per stage27/29/32/34/35 dB(A)29/31/32/33/35 dB(A)31/33/35/37/39 dB(A)34/36/38/40/42 dB(A)31/34/37/40/42 dB(A)35/39/41/43/45 dB(A)37/40/42/44/47 dB(A)
Power supply230/1~/50 V/Ph/Hz230/1~/50 V/Ph/Hz230/1~/50 V/Ph/Hz230/1~/50 V/Ph/Hz230/1~/50 V/Ph/Hz230/1~/50 V/Ph/Hz230/1~/50 V/Ph/Hz
Electr. nominal power consumption40 W40 W70 W90 W70 W150 W170 W
Electr. nominal current consumption0,20 A0,24 A0,35 A0,44 A0,38 A0,68 A0,78 A
Operation pressure, max.1400 kPa1400 kPa1400 kPa1400 kPa1400 kPa1400 kPa1400 kPa
Medium connections3/4 inch3/4 inch3/4 inch3/4 inch3/4 inch3/4 inch3/4 inch
Nominal medium flow0,53 m³/h0,57 m³/h0,75 m³/h0,84 m³/h1,22 m³/h1,39 m³/h1,45 m³/h
Nominal pressure loss, internal ²)15,0 kPa18,0 kPa25,0 kPa20,0 kPa30,0 kPa38,0 kPa42,0 kPa
Medium volume cooling coil / heating coil1,3 l1,3 l1,3 l1,79 l2,84 l3,22 l3,22 l
Dimensions ceiling cassette h/b/t258/570/570 mm258/570/570 mm258/570/570 mm298/570/570 mm298/570/1110 mm298/570/1110 mm298/570/1110 mm
Dimensions grille h/w/d28/650/650 mm28/650/650 mm28/650/650 mm28/650/650 mm28/690/1220 mm28/690/1220 mm28/690/1220 mm
Weight28 kg28 kg28 kg31 kg57 kg59 kg59 kg
Series colorweiß weiß weiß weiß weiß weiß weiß

Accessories / Spare parts

Variant
Loading ...
Loading ...

Downloads

Variant
Language
Pictures
REMKO KWD 25 jpg, 1,272,909,000.0
Assembly drawings
REMKO KWD 25 jpg, 55,200,000.0

Cooling load calculation for air-conditioners

The following rule of thumb applies when calculating the cooling capacity:
Approximately 30 W of cooling capacity are required per cubic meter. The cooling capacity for a room with a surface area of 28 m2 and height of 2.5 m can be calculated as follows:

28 m2 x 2,5 m x 30 W/m3 = 2.100 Watt (2,1 kW)

We recommend that you always calculate the cooling capacity for the room precisely.

Cooling load calculation Calculate required cooling capacity